40 CFR Part 63, Table 30 — Roof Fitting Loss Factors, KFa, KFb, and m, a and Typical Number of Fittings, NT

Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
Fitting type and construction detailsLoss factors bTypical number of fittings, NT
KFa (lb-mole/yr)KFb (lb-mole/[mi/hr]m-yr)m (dimensionless)
Access hatch (24-in-diameter well)|| 1
Bolted cover, gasketed00 | c 0 |
Unbolted cover, ungasketed2.77.1 | 1 |
Unbolted cover, gasketed2.90.41 | 1 |
Unslotted guide-pole well (8-in-diameter unslotted pole, 21-in-diameter well)|| 1
Ungasketed sliding cover067 | c 0.98 |
Gasketed sliding cover03 | 1.4 |
Slotted guide-pole/sample well (8-in-diameter unslotted pole, 21-in-diameter well)|| (d).
Ungasketed sliding cover, without float0310 | 1.2 |
Ungasketed sliding cover, with float029 | 2 |
Gasketed sliding cover, without float0260 | 1.2 |
Gasketed sliding cover, with float08.5 | 1.4 |
Gauge-float well (20-inch diameter)|| 1
Unbolted cover, ungasketed2.35.9 | c 1.0 |
Unbolted cover, gasketed2.40.34 | 1 |
Bolted cover, gasketed00 | 0 |
Gauge-hatch/sample well (8-inch diameter)|| 1
Weighted mechanical actuation, gasketed0.950.14 | c 1.0 |
Weighted mechanical actuation, ungasketed0.912.4 | 1 |
Vacuum breaker (10-in-diameter well)|| NF6 (Table 31).
Weighted mechanical actuation, gasketed1.20.17 | c 1.0 |
Weighted mechanical actuation, ungasketed1.23 | 1 |
Roof drain (3-in-diameter)|| NF7 (Table 31).
Open07 | e 1.4 | NF8 (Table 32 f).
90 percent closed0.510.81 | 1 |
Roof leg (3-in-diameter)|| NF8 (Table 32 f).
Adjustable, pontoon area1.50.2 | c 1.0 |
Adjustable, center area0.250.067 | c 1.0 |
Adjustable, double-deck roofs0.250.067 | 1 |
Fixed00 | 0 |
Roof leg (21⁄2-in-diameter)|| NF8 (Table 32 f).
Adjustable, pontoon area1.70 | 0 |
Adjustable, center area0.410 | 0 |
Adjustable, double-deck roofs0.410 | 0 |
Fixed00 | 0 |
Rim vent (6-in-diameter)|| 1 g.
Weighted mechanical actuation, gasketed0.710.1 | c 1.0 |
Weighted mechanical actuation, ungasketed0.681.8 | 1.0 |

a The roof fitting loss factors, KFa, KFb, and m, may only be used for wind speeds from 2 to 15 miles per hour.

b Unit abbreviations are as follows: lb = pound; mi = miles; hr = hour; yr = year.

c If no specific information is available, this value can be assumed to represent the most common or typical roof fittings currently in use.

d A slotted guide-pole/sample well is an optional fitting and is not typically used.

e Roof drains that drain excess rainwater into the product are not used on pontoon floating roofs. They are, however, used on double-deck floating roofs and are typically left open.

f The most common roof leg diameter is 3 inches. The loss factors for 21⁄2-inch diameter roof legs are provided for use if this smaller size roof is used on a particular floating roof.

g Rim vents are used only with mechanical-shoe primary seals.